Power Quality and Drives LLC
search:
Home




Contactors


Motor Overload Protection


Inverter Duty Motors

Variable Frequency Drives
Type 1 Enclosure


Variable Frequency Drives
with Built-in EMC Filter
and DC Reactor
Type 1 and Type 12
Enclosures


Variable Frequency Drives
with MCP Disconnect
Type 1 Enclosure




UL Type 1 Enclosed
NEMA Rated Starters
with No Pushbuttons


ON and OFF Pushbuttons

Combination Start, Stop

HOA and CPT

Combination HOA



UL Type 4/12 Enclosed
NEMA Rated Starters
Start and Stop Pushbuttons


Combination Start, Stop

HOA and CPT

Combination HOA

Reversing

Combination Reversing


Explosionproof Control
Non-Combination Starters


Explosionproof Control
Combination Starters


Explosionproof Combination with Ground Fault

Hazardous Location Switches

Explosionproof
Oher Equipment




Starters Open

Reversing Starters Open

Enclosures

Solid State Reduced Voltage





Contactors

Reversing Contactors

Solid State Contactors

Pressure Transducers

Lightning/Surge Suppressors



Pump Control
Simplex


Duplex Manual or Automatic Alternation
1 Float Switch Control
Non-combination


Duplex Manual or Automatic Alternation
1 Float Switch Control
Combination


Duplex Manual or Automatic Alternation
1 or 2 Float Switch Control
Non-combination


Duplex Lead/Lag
3, 4, or 5
Float Switch Control
Non-combination


Duplex Lead/Lag
3, 4, or 5
Float Switch Control
Combination


Variable Frequency Drive
Pump Packages
Single and Three Phase
Type 3R Enclosure







All Products Listed


If you don't see it . . .

Store Policies



Contact Us


















Items: 0
Total: $0.00




Home > Store > Pump Control Lead-Lag Non-Combination > NEMA Size 2, 8 to 40 Amps, 10 HP @ 200 VAC, 10 HP @ 230 VAC, 25 HP @ 460 VAC, 30 HP @ 575 VAC, UL Type 4
 

NEMA Size 2, 8 to 40 Amps, 10 HP @ 200 VAC, 10 HP @ 230 VAC, 25 HP @ 460 VAC, 30 HP @ 575 VAC, UL Type 4

Product #:  APX4-50/J-40
Brand:  Cerus Industrial
Description: 
3 Pole, 50 Amp, NEMA Size 2 Contactor,
1 or 3 Phase
5kAIC @ 460 VAC
 
7 to 10 business days to ship except as noted below for special options.
 
UL Type 4 Steel Enclosure
(Indoor or outdoor use to provide a degree of protection against falling rain,
splashing water, and hose-directed water; undamaged by the formation of
ice on the enclosure.)

Provision for three, four, or five float switch control:
Stop, Lead Pump Start, Lag Pump Start, High Level Alarm,
plus optional Low Level Alarm.

Automatic alternation with each on and off cycle.
Additional alternations during extended periods of run time are programmable for up to seven days.
(See below attached "Duplex PLC Wiring").

Lag pump automatically replaces failed Lead pump.

PLC based.

Fault and Alarm contact outputs are available for use with external devices.

Control Power Transformer, 208, 240, 277, or 480 VAC primary, 120 VAC Secondary.

120 or 575 VAC Power Input is available upon request.

Full Voltage, Non-reversing.


Mounted on the door:
PUMP 1 HAND-OFF-AUTO
Pump 1 ON light (Green)

Pump 2 HAND-OFF-AUTO 
Pump 2 ON light (Green)
 
High Level Alarm pilot light (Red)


Internal features:
Adjustable time for Lag Start delay up to 60 seconds.
LED indicator for float switch failure - identifies the specific float switch.
Provision for customer supplied enable switch with the removal of Jumper JE1.

Magnetic trip short circuit protection for each motor.
Electronic Overload Relay for each motor, Model CRP.
(For power wiring, see below attached Duplex Motor Wiring).

Float switches are not included.

Available options:
Single Phase input for single phase motors - specify when ordering (no charge)
Low Level Alarm - optional fifth float switch control (no charge)
Fault Pilot Lights
Digital Hour Meters, one meter for each pump
Alarm Beacon Light
Door Mounted Horn with Silence Pushbutton
Door Mounted Buzzer with Silence Pushbutton
Leak Seal Relays  (Motor seal failure relay for each pump - Motor should have
    a resistive float switch or probe)
Motor overheat relay (motor should have an internal thermostat)
120 VAC output for external alarm light

Available options at additional cost and longer than 7 to 10 days to ship:
Lightning Arrestor/Sure Suppressor Model LA603
Larger than Size 3 Starter
UL Type 4X Enclosure
Explosion-Proof Enclosure

Link for the PLC manual:
http://www.cerusind.com/catalog/documents/Manuals/K120S_PLC_Manual.pdf

Overload Relay Model CRP-40  

Adjustable Trip Amps from 8 to 40 Amps, no heaters required.
Solid-state Microprocessor Based
Class 1 to 30 infinitely selectable via trip time setting: adjust from 0 to 30 Seconds, the time you set is the trip time at six times the set current. Example: 10 seconds will give a Class 10 trip.
Operational Temperature: -25 to +70 degrees C
 
Protections:
Phase current unbalance
Phase loss/phase failure
Stall Protection
 
Phase current unbalance: trips within 5 seconds when the phase current unbalance exceeds 50%.
 
Phase loss/phase failure: trips within 3 seconds when phase current is 70% unbalanced.
 
Stall Protection: Trips at 170% of full load amps at 3 seconds.
 
LED indication of faults for over current, phase failure.
 
 
Specify motor HP, Voltage, Full Load Amps, Phase, and Frequency when ordering.
 
Three Phase
10 HP @ 200 VAC
10 HP @ 230 VAC
25 HP @ 460 VAC
30 HP @ 575 VAC
 
Single Phase 
3 HP @ 115 VAC
7.5 HP @ 230 VAC
 
Shipping by ground UPS is included.
You may order by telephone: (203) 217-2353
Please have the following information:
Credit Card number
Expiration date
Name on the card
Credit Card billing address
Shipping address
 
Price:  $2393.00
Bookmark and Share




Price: $2393.00
  


Power Quality and Drives LLC
P.O. Box 83
7 Yale Avenue
Middlebury, CT  06762
USA
Phone: (203) 217-2353