Pump Control, NEMA Size 1, 8 to 32 Amps, 230 or 460 VAC

Product #:  CIE3R-32/P-ACJX
Brand:  Cerus Industrial
Description:  Service Entrance Rated Fusible Disconnect, 60 Amp
NEMA 3R Enclosure
NEMA Size 1 Starter, 3 Phase, 60 Hz, 230/460 VAC
32 Amp Contactor, 120 VAC Coil
Model CRP Solid State Overload Relay,
adjustable 8 to 32 Amps.


Rain Tight Hub as shown in picture is not included.

Control Power Transformer,
230 x 460 VAC Primary, 115 VAC Secondary, will be connected for 460 VAC. Reconnect the primary if the power source and motor are rated 230 VAC.


Select a control according to the Disconnect Size and Fuse Size needed as per NEC Article 430.52.

20 HP @ 460 VAC
10 HP @ 230 VAC

Run Pilot Light (Red), Off Pilot Light (Green), Hand-Off-Auto, Start Pushbutton, Overload Reset mounted on door.
Will accept customer supplied remote contact closure in Auto.

Model CRP Overload Relay:
Adjustable Trip Amps
Solid-state Microprocessor Based
Class 1 to 30 infinitely selectable via trip time setting:
0 to 30 Seconds, set time is the trip time at six times the
set current.
Operational Temperature: -25 to +70 degrees C

Protections:
Phase current unbalance
Phase loss/phase failure
Stall Protection

Phase current unbalance: trips within 5 seconds when the phase current unbalance exceeds 50%.

Phase loss/phase failure: trips within 3 seconds when phase current is 70% unbalanced.

Stall Protection: Trips at 170% of full load amps at 3 seconds.

LED indication of faults for over current, phase failure.

Lightning Arrestor rated at 2000 clamping volts at
60,000 Amps Surge.
Over 60,000 Amps to 100,000 Amps will be passed but Arrestor will need replacement.

600 VAC, Time Delay, Current Limiting Fuses, Class J, are required.
Fuses are not included.

Four weeks to ship. Allow additional time for transit from the shipping point in Oregon.
Shipping by ground freight is included in the price.

Price:  $1005.00
Email this page to a friend

Pump Control


Price: $1005.00
  


Power Quality and Drives LLC
P.O. Box 83
7 Yale Avenue
Middlebury, CT  06762
USA
Phone: (203) 217-2353
© Copyright 2009 - Power Quality and Drives LLC
Privacy Policy