Power Quality and Drives LLC
search:
Home
Contactors
Motor Overload Protection
Inverter Duty Motors
Variable Frequency Drives
Type 1 Enclosure
Variable Frequency Drives
with Built-in EMC Filter
and DC Reactor
Type 1 and Type 12
Enclosures
Variable Frequency Drives
with MCP Disconnect
Type 1 Enclosure
UL Type 1 Enclosed
NEMA Rated Starters
with No Pushbuttons
ON and OFF Pushbuttons
Combination Start, Stop
HOA and CPT
Combination HOA
UL Type 4/12 Enclosed
NEMA Rated Starters
Start and Stop Pushbuttons
Combination Start, Stop
HOA and CPT
Combination HOA
Reversing
Combination Reversing
Explosionproof Control
Non-Combination Starters
Explosionproof Control
Combination Starters
Explosionproof Combination with Ground Fault
Hazardous Location Switches
Explosionproof
Oher Equipment
Starters Open
Reversing Starters Open
Enclosures
Solid State Reduced Voltage
Contactors
Reversing Contactors
Solid State Contactors
Pressure Transducers
Lightning/Surge Suppressors
Pump Control
Simplex
Duplex Manual or Automatic Alternation
1 Float Switch Control
Non-combination
Duplex Manual or Automatic Alternation
1 Float Switch Control
Combination
Duplex Manual or Automatic Alternation
1 or 2 Float Switch Control
Non-combination
Duplex Lead/Lag
3, 4, or 5
Float Switch Control
Non-combination
Duplex Lead/Lag
3, 4, or 5
Float Switch Control
Combination
Variable Frequency Drive
Pump Packages
Single and Three Phase
Type 3R Enclosure
All Products Listed
If you don't see it . . .
Store Policies
Contact Us
Items: 0
Total: $0.00
Home
>
Store
>
Reduced Voltage Starters, Solid State
>
125 Amp, UL Type 1 Enclosure
125 Amp, UL Type 1 Enclosure
Product #:
MS6-125-N1
Brand:
Cerus Industrial
Description:
Solid State Reduced Voltage Starter
3 PH, 50/60Hz,
200 to 600 VAC
Customer supplied 1/60/120 or 1/50/115 AC power input is required for control circuitry.
Non-Reversing
Ramp Up
Ramp Down or Coast to Stop
125 Amp Output
50 HP @ 240 V
100 HP @ 480 V
125 HP @ 575 V
Step Current: 100 to 400% Motor FLA
Ramp Current: Ramp from Step Current to maximum of 500% Motor FLA or limit current to Step Current setting.
Two or three wire control
120 VAC control inputs for:
Start Stop
Jog Reverse
Reset
Enable
Keypad and LCD display for starter setup and diagnostics
Single phase protection
Phase rotation insensitive
Instantaneous over-current trip Class 10, 15, 20, or 30 electronic motor overload
Shorted SCR Fault output
Shear pin
Fault Dry contact relay outputs for:
Fault By-pass
Shorted SCR
Running Reverse
1600V PIV SCR’s